BT Series (Single Piston)
Application: Used for special application solutions.

Setting Parameters:

Tightening time
Welding time
Welding Power
Cooling time
Operation interval time
Automatic / Manual Operating time
Operation: When the pedal is depressed, the piston is activated and the tightening time starts to count down. The welding process starts when the spin-out period is over. Applies the welding power up to the set welding time. When finished, the plunger continues to hold the boiling part during the cooling time. At the end of the cooling period, the piston leaves and waits for the next operation to release the pedal and press it again. If automatic mode is selected, the pedal is held depressed. At the end of the process, the system waits for the set Process interval and starts the new operation. The process interval time is the time required to remove the boiling part and make the new part ready for welding.