The Spark series which produced by Özen compressors, coupled structure with excellent design formed compressor, dryer and air tank is carefully combined with the series.
SPACE SAVING
Compressor, air receiver and dryer assembled together occupy less space than located separately.
INDEPENDENT WORKING
The units forming system have separate control panels, if necessary, allows compressor and dryer to operate separately.
COUPLED STRUCTURE ADVANTAGE
Units in the system connected each other with short connections for banning possible pressure drops. Couple structure also avoidpossible oil leakages.
SPARK SERIES TANK MOUNTED INVERTER CONTROLLED SCREW AIR COMPRESSORS
EASE OF SERVICE
Coupled design provides extensive interior volume, will allow easy service and maintenance. It is possible reach directly to components which require maintenance or repair, during any process does not require touch or remove any other equipment or part.
QUALITY EQUIPMENT
Ozen Compressors produced air tank is tested with 2,5 times more than working pressure. The system consist Ozen compressors produced quality connection equipments which provide trouble-free operation for long years.
INVERTER APPLICATION
Frequency inverter can be applied as optional to Spark Series. By this way beside of space-saving, easy installation and easy maintenance advantages from Spark up to 35% energy savings can be achieved through use of frequency inverters.
SPARK SERIES TANK MOUNTED SCREW AIR COMPRESSORS
MODEL | TANK VOLUME (lt.) | AIR FLOW | DRYER AND EQUIPPED LINE FILTERS MODELS | MOTOR POWER | WEIGHT (kg.) | ||||||
m³/dk @ 7,5 BAR | m³/dk @ 10 BAR | m³/dk @ 13 BAR | |||||||||
min | max | min | max | min | max | kw | hp | ||||
OSC 3 T | 300 | 340 | 0,34 | 230 | 0,23 | 170 | 0,17 | - | 2,2 | 3 | 230 |
OSC 3 TD | 300 | 340 | 0,34 | 230 | 0,23 | 170 | 0,17 | "ODR 30 - OFL 50 X-Y - 1/2 | 2,2 | 3 | 250 |
OSC 4 T | 300 | 490 | 0,49 | 390 | 0,39 | 270 | 0,27 | - | 3 | 4 | 245 |
OSC 4 TD | 300 | 490 | 0,49 | 390 | 0,39 | 270 | 0,27 | "ODR 30 - OFL 50 X-Y - 1/2 | 3 | 4 | 290 |
OSC 5 T | 300 | 660 | 0,66 | 550 | 0,55 | 390 | 0,39 | - | 4 | 5,5 | 270 |
OSC 5 TD | 300 | 660 | 0,66 | 550 | 0,55 | 390 | 0,39 | "ODR 42 - OFL 50 X-Y - 1/2 | 4 | 5,5 | 310 |
OSC 7 T | 500 | 900 | 0,90 | 730 | 0,73 | 610 | 0,61 | - | 5,5 | 7,5 | 380 |
OSC 7 TD | 500 | 900 | 0,90 | 730 | 0,73 | 610 | 0,61 | "ODR 66 - OFL 50 X-Y - 3/4 | 5,5 | 7,5 | 430 |
OSC 10 T | 500 | 1.280 | 1,28 | 1010 | 1,01 | 810 | 0,81 | - | 7,5 | 10 | 400 |
OSC 10 TD | 500 | 1.280 | 1,28 | 1010 | 1,01 | 810 | 0,81 | "ODR 66 - OFL 150 X-Y - 3/4 | 7,5 | 10 | 475 |
OSC 15 T | 500 | 2.010 | 2,01 | 1.840 | 1,84 | 1.490 | 1,49 | - | 11 | 15 | 440 |
OSC 15 TD | 500 | 2.010 | 2,01 | 1.840 | 1,84 | 1.490 | 1,49 | "ODR 130 - OFL 150 X-Y - 3/4 | 11 | 15 | 510 |
OSC 15T-1 | 1000 | 2.010 | 2,01 | 1.840 | 1,84 | 1.490 | 1,49 | - | 11 | 15 | 560 |
OSC 15 TD-1 | 1000 | 2.010 | 2,01 | 1.840 | 1,84 | 1.490 | 1,49 | "ODR 130 - OFL 150 X-Y - 3/4 | 11 | 15 | 620 |
OSC 20 T | 500 | 2.750 | 2,75 | 2.350 | 2,35 | 2.000 | 2,00 | - | 15 | 20 | 490 |
OSC 20 TD | 500 | 2.750 | 2,75 | 2.350 | 2,35 | 2.000 | 2,00 | "ODR 168 - OFL 500 X-Y - 1 1/2 | 15 | 20 | 575 |
OSC 20 T-1 | 1000 | 2.750 | 2,75 | 2.350 | 2,35 | 2.000 | 2,00 | - | 15 | 20 | 645 |
OSC 20 TD-1 | 1000 | 2.750 | 2,75 | 2.350 | 2,35 | 2.000 | 2,00 | "ODR 168 - OFL 500 X-Y - 1 1/2 | 15 | 20 | 710 |
OSC 25 T | 1000 | 3.400 | 3,40 | 2.600 | 2,60 | 2.400 | 2,40 | - | 18,5 | 25 | 715 |
OSC 25 TD | 1000 | 3.400 | 3,40 | 2.600 | 2,60 | 2.400 | 2,40 | "ODR 240 - OFL 500 X-Y - 1 1/2 | 18,5 | 25 | 790 |
OSC 30 T | 1000 | 3.900 | 3,90 | 3.200 | 3,20 | 2.600 | 2,60 | - | 22 | 30 | 730 |
OSC 30 TD | 1000 | 3.900 | 3,90 | 3.200 | 3,20 | 2.600 | 2,60 | "ODR 240 - OFL 500 X-Y - 1 1/2 | 22 | 30 | 820 |
Air flows mentioned according to ISO 1217 standard at 20 ° C ambient temperature and 1 bar inlet pressure. Air flow Tolerance: -/+ 6% |
OSC T Model: The system formed with screw compressor and air receiver
OSC TD Model: The system formed with screw compressor, air receiver and refrigerated air dryer as well as equipped inlet and outlet line filters
SPARK SERIES TANK MOUNTED INVERTER CONTROLLED SCREW AIR COMPRESSORS
MODEL | TANK VOLUME (lt.) | AIR FLOW | DRYER AND EQUIPPED LINE FILTERS MODELS | MOTOR POWER | WEIGHT (kg.) | ||||||
m³/dk @ 7,5 BAR | m³/dk @ 10 BAR | m³/dk @ 13 BAR | |||||||||
min | max | min | max | min | max | kw | hp | ||||
OSC 3 TV | 200 | 0,1 | 0,34 | 0,08 | 0,23 | 0,07 | 0,17 | - | 2,2 | 3 | 242 |
OSC 3 TDV | 200 | 0,1 | 0,34 | 0,08 | 0,23 | 0,07 | 0,17 | ODR 30 - OFL 50 X-Y - 1/2 | 2,2 | 3 | 262 |
OSC 4 TV | 200 | 0,1 | 0,49 | 0,08 | 0,39 | 0,07 | 0,27 | - | 3 | 4 | 257 |
OSC 4 TDV | 200 | 0,1 | 0,49 | 0,08 | 0,39 | 0,07 | 0,27 | ODR 30 - OFL 50 X-Y - 1/2 | 3 | 4 | 302 |
OSC 5 TV | 300 | 0,1 | 0,66 | 0,08 | 0,55 | 0,07 | 0,39 | - | 4 | 5,5 | 282 |
OSC 5 TDV | 300 | 0,1 | 0,66 | 0,08 | 0,55 | 0,07 | 0,39 | ODR 42 - OFL 50 X-Y - 1/2 | 4 | 5,5 | 322 |
OSC 7 TV | 500 | 0,1 | 0,90 | 0,08 | 0,73 | 0,07 | 0,61 | - | 5,5 | 7,5 | 398 |
OSC 7 TDV | 500 | 0,1 | 0,90 | 0,08 | 0,73 | 0,07 | 0,61 | ODR 66 - OFL 150 X-Y - 3/4 | 5,5 | 7,5 | 448 |
OSC 10 TV | 500 | 0,24 | 1,28 | 0,23 | 1,01 | 0,21 | 0,81 | - | 7,5 | 10 | 418 |
OSC 10 TDV | 500 | 0,24 | 1,28 | 0,23 | 1,01 | 0,21 | 0,81 | ODR 66 - OFL 150 X-Y - 3/4 | 7,5 | 10 | 493 |
OSC 15 TV | 500 | 0,69 | 2,01 | 0,66 | 1,84 | 0,66 | 1,49 | - | 11 | 15 | 458 |
OSC 15 TDV | 500 | 0,69 | 2,01 | 0,66 | 1,84 | 0,66 | 1,49 | ODR 130 - OFL 150 X-Y - 3/4 | 11 | 15 | 528 |
OSC 15 T-1V | 1000 | 0,69 | 2,01 | 0,66 | 1,84 | 0,66 | 1,49 | - | 11 | 15 | 578 |
OSC 15 TD-1V | 1000 | 0,69 | 2,01 | 0,66 | 1,84 | 0,66 | 1,49 | ODR 130 - OFL 150 X-Y - 3/4 | 11 | 15 | 638 |
OSC 20 TV | 500 | 0,69 | 2,75 | 0,66 | 2,35 | 0,66 | 2,00 | - | 15 | 20 | 518 |
OSC 20 TDV | 500 | 0,69 | 2,75 | 0,66 | 2,35 | 0,66 | 2,00 | ODR 168 - OFL 500 X-Y - 1 1/2 | 15 | 20 | 603 |
OSC 20 T-1V | 1000 | 0,69 | 2,75 | 0,66 | 2,35 | 0,66 | 2,00 | - | 15 | 20 | 673 |
OSC 20 TD-1V | 1000 | 0,69 | 2,75 | 0,66 | 2,35 | 0,66 | 2,00 | ODR 168 - OFL 500 X-Y - 1 1/2 | 15 | 20 | 738 |
OSC 25 TV | 1000 | 0,69 | 3,40 | 0,66 | 2,60 | 0,66 | 2,40 | - | 18,5 | 25 | 743 |
OSC 25 TDV | 1000 | 0,69 | 3,40 | 0,66 | 3,60 | 0,66 | 2,40 | ODR 240 - OFL 500 X-Y - 1 1/2 | 18,5 | 25 | 818 |
OSC 30 TV | 1000 | 0,69 | 3,90 | 0,66 | 3,20 | 0,66 | 2,60 | - | 22 | 30 | 758 |
OSC 30 TDV | 1000 | 0,69 | 3,90 | 0,66 | 3,20 | 0,66 | 2,60 | ODR 240 - OFL 500 X-Y - 1 1/2 | 22 | 30 | 848 |